Câble U 1000 RGPFV-RH 0.6/1kV – الشركة المصنعة للكابل

مقدمة

ال Câble U 1000 RGPFV-RH 0.6/1kV is a low-voltage power and control cable widely used in industrial and infrastructure applications where high mechanical protection, الموثوقية الكهربائية, and long service life are required. Designed according to European practices and compliant with IEC standards, this cable type is suitable for fixed installations in demanding environments, including underground installations, النباتات الصناعية, energy facilities, and public infrastructure projects.

Low-voltage cables rated at 0.6/1kV form the backbone of modern power distribution systems. Among them, Câble U 1000 RGPFV-RH 0.6/1kV stands out due to its robust construction, combining copper conductors, العزل XLPE, protective metallic layers, and durable outer sheathing. This combination ensures safe and stable operation even under harsh mechanical and environmental conditions.

Câble U 1000 RGPFV-0.6-1كيلو فولت

What Is Câble U 1000 RGPFV-RH 0.6/1kV?

Câble U 1000 RGPFV-RH 0.6/1kV is a fixed-installation low-voltage cable designed for power distribution and control circuits. The designation generally reflects its construction and performance characteristics:

  • U 1000: Rated voltage 0.6/1kV
  • ر: موصل النحاس
  • G: Insulation and bedding suitable for fixed installation
  • P: Lead sheath providing moisture and chemical protection
  • F: Steel tape armour for mechanical protection
  • الخامس: PVC outer sheath
  • RH: Enhanced resistance to hydrocarbons and aggressive environments

Thanks to this structure, the cable is suitable for indoor, outdoor, and underground installations where additional mechanical protection is required.

Applicable Standards and Compliance

The design and manufacture of Câble U 1000 RGPFV-RH 0.6/1kV typically comply with the following international and European standards:

  • اللجنة الانتخابية المستقلة 60228: Conductors of insulated cables
  • اللجنة الانتخابية المستقلة 60502-1: Power cables with extruded insulation for rated voltages up to 1kV
  • اللجنة الانتخابية المستقلة 60332: Tests on electric cables under fire conditions
  • اللجنة الانتخابية المستقلة 60811: Common test methods for insulating and sheathing materials

Compliance with these standards ensures consistent electrical performance, القوة الميكانيكية, flame retardancy, والموثوقية على المدى الطويل.

U 1000 RGPFV-RH Cable

بناء الكابلات

The performance of Câble U 1000 RGPFV-RH 0.6/1kV is directly related to its carefully engineered multi-layer structure.

موصل النحاس

The conductor is made of high-purity electrolytic copper, ensuring excellent electrical conductivity. According to اللجنة الانتخابية المستقلة 60228, conductors are typically:

  • فصل 1 (صلب) for smaller cross-sections
  • فصل 2 (stranded) for medium and large cross-sections

عزل XLPE

البولي إيثيلين المتقاطع (XLPE) insulation provides high dielectric strength, low dielectric losses, and good thermal resistance. XLPE allows higher operating temperatures compared to traditional PVC insulation.

Inner Sheath and Bedding

An inner sheath or bedding layer helps maintain the cable geometry and provides a smooth surface for the metallic layers.

غلاف ارصاص

The lead sheath offers excellent protection against moisture, دخول الماء, and chemical attack, making the cable suitable for underground and industrial environments.

Steel Tape Armour

Steel tape armour (STA) provides strong mechanical protection against external impacts, crushing forces, and rodent damage.

PVC Outer Sheath

The PVC outer sheath protects the cable against abrasion, الأشعة فوق البنفسجية, oils, hydrocarbons, and environmental exposure.

Electrical Characteristics

Câble U 1000 RGPFV-RH 0.6/1kV is designed to operate reliably in low-voltage distribution systems.

  • الفولطية: 0.6/1كيلو فولت
  • Maximum conductor operating temperature: typically up to 90°C (XLPE)
  • درجة حرارة الدائرة القصيرة: up to 250°C (for a limited duration)
  • Low electrical resistance due to copper conductors

The electrical performance depends on the selected conductor cross-section, installation conditions, and ambient temperature.

Câble U 1000 RGPFV-RH 0.6-1kV

Mechanical and Environmental Performance

Thanks to its reinforced construction, Câble U 1000 RGPFV-RH 0.6/1kV العروض:

  • High resistance to mechanical stress
  • Excellent moisture and water resistance
  • Good resistance to oils, fuels, and hydrocarbons
  • Reliable performance in underground installations
  • عمر خدمة طويل, often exceeding 30 years when properly installed

These properties make the cable suitable for demanding industrial and infrastructure applications.

التطبيقات النموذجية

Câble U 1000 RGPFV-RH 0.6/1kV is commonly used in:

  • Industrial power distribution systems
  • Manufacturing plants and processing facilities
  • Power supply lines for heavy equipment
  • Underground and buried installations
  • Energy and utility infrastructure
  • Public buildings and large commercial complexes

Its robust design ensures safe and continuous operation even in harsh environments.

IEC Conductor Sizes for Câble U 1000 RGPFV-RH 0.6/1kV

The following table lists IEC conductor cross-sectional areas from 0.75 mm² up to 800 مم², commonly referenced for low-voltage power cables in accordance with اللجنة الانتخابية المستقلة 60228. Actual availability may vary depending on manufacturer and project requirements.

حجم الموصل (مم²)IEC Classتطبيق نموذجي
0.75فصل 2Control and signal circuits
1.0فصل 2Control wiring
1.5فصل 1 / 2Lighting and control
2.5فصل 2Small power circuits
4فصل 2Power distribution
6فصل 2Medium-load circuits
10فصل 2Industrial power supply
16فصل 2Power feeders
25فصل 2Main distribution lines
35فصل 2Heavy-duty power supply
50فصل 2High-load distribution
70فصل 2Industrial feeders
95فصل 2Large equipment supply
120فصل 2High-current circuits
150فصل 2Main power lines
185فصل 2Industrial main feeders
240فصل 2High-power applications
300فصل 2Specialized installations
400فصل 2Large-scale power systems
500فصل 2Very high current supply
630فصل 2Industrial heavy-load lines
800فصل 2Special large-capacity projects

اعتبارات التثبيت

When installing Câble U 1000 RGPFV-RH 0.6/1kV, the following factors should be considered:

  • Minimum bending radius according to cable diameter
  • Proper trench preparation for underground installation
  • Adequate mechanical protection at entry and exit points
  • Compliance with local electrical installation codes

Correct installation practices are essential to fully benefit from the cable’s mechanical and electrical performance.

Câble U 1000 RGPFV-RH 0.6-1kV Manufacturer

Advantages of Câble U 1000 RGPFV-RH 0.6/1kV

Key advantages include:

  • High mechanical strength due to steel tape armour
  • Excellent moisture and chemical resistance from lead sheath
  • Reliable electrical performance with XLPE insulation
  • Wide range of IEC conductor sizes available
  • Long service life and low maintenance requirements

These advantages make the cable a preferred solution for critical low-voltage installations.

Câble U 1000 RGPFV-RH 0.6/1kV

Câble U 1000 RGPFV-RH 0.6/1kV is a robust and versatile low-voltage power cable designed for demanding fixed installations. Its combination of copper conductors, العزل XLPE, غمد الرصاص, steel tape armour, and PVC outer sheath ensures excellent electrical reliability, الحماية الميكانيكية, والمقاومة البيئية.

With IEC conductor sizes ranging from 0.75 ملم² إلى 800 مم², this cable type can be adapted to a wide variety of power and control applications. For industrial plants, مشاريع البنية التحتية, and underground power distribution systems, Câble U 1000 RGPFV-RH 0.6/1kV remains a dependable and proven solution.