مقدمة
ال Câble U 1000 RGPFV-RH 0.6/1kV is a low-voltage power and control cable widely used in industrial and infrastructure applications where high mechanical protection, الموثوقية الكهربائية, and long service life are required. Designed according to European practices and compliant with IEC standards, this cable type is suitable for fixed installations in demanding environments, including underground installations, النباتات الصناعية, energy facilities, and public infrastructure projects.
Low-voltage cables rated at 0.6/1kV form the backbone of modern power distribution systems. Among them, Câble U 1000 RGPFV-RH 0.6/1kV stands out due to its robust construction, combining copper conductors, العزل XLPE, protective metallic layers, and durable outer sheathing. This combination ensures safe and stable operation even under harsh mechanical and environmental conditions.

What Is Câble U 1000 RGPFV-RH 0.6/1kV?
Câble U 1000 RGPFV-RH 0.6/1kV is a fixed-installation low-voltage cable designed for power distribution and control circuits. The designation generally reflects its construction and performance characteristics:
- U 1000: Rated voltage 0.6/1kV
- ر: موصل النحاس
- G: Insulation and bedding suitable for fixed installation
- P: Lead sheath providing moisture and chemical protection
- F: Steel tape armour for mechanical protection
- الخامس: PVC outer sheath
- RH: Enhanced resistance to hydrocarbons and aggressive environments
Thanks to this structure, the cable is suitable for indoor, outdoor, and underground installations where additional mechanical protection is required.
Applicable Standards and Compliance
The design and manufacture of Câble U 1000 RGPFV-RH 0.6/1kV typically comply with the following international and European standards:
- اللجنة الانتخابية المستقلة 60228: Conductors of insulated cables
- اللجنة الانتخابية المستقلة 60502-1: Power cables with extruded insulation for rated voltages up to 1kV
- اللجنة الانتخابية المستقلة 60332: Tests on electric cables under fire conditions
- اللجنة الانتخابية المستقلة 60811: Common test methods for insulating and sheathing materials
Compliance with these standards ensures consistent electrical performance, القوة الميكانيكية, flame retardancy, والموثوقية على المدى الطويل.

بناء الكابلات
The performance of Câble U 1000 RGPFV-RH 0.6/1kV is directly related to its carefully engineered multi-layer structure.
موصل النحاس
The conductor is made of high-purity electrolytic copper, ensuring excellent electrical conductivity. According to اللجنة الانتخابية المستقلة 60228, conductors are typically:
- فصل 1 (صلب) for smaller cross-sections
- فصل 2 (stranded) for medium and large cross-sections
عزل XLPE
البولي إيثيلين المتقاطع (XLPE) insulation provides high dielectric strength, low dielectric losses, and good thermal resistance. XLPE allows higher operating temperatures compared to traditional PVC insulation.
Inner Sheath and Bedding
An inner sheath or bedding layer helps maintain the cable geometry and provides a smooth surface for the metallic layers.
غلاف ارصاص
The lead sheath offers excellent protection against moisture, دخول الماء, and chemical attack, making the cable suitable for underground and industrial environments.
Steel Tape Armour
Steel tape armour (STA) provides strong mechanical protection against external impacts, crushing forces, and rodent damage.
PVC Outer Sheath
The PVC outer sheath protects the cable against abrasion, الأشعة فوق البنفسجية, oils, hydrocarbons, and environmental exposure.
Electrical Characteristics
Câble U 1000 RGPFV-RH 0.6/1kV is designed to operate reliably in low-voltage distribution systems.
- الفولطية: 0.6/1كيلو فولت
- Maximum conductor operating temperature: typically up to 90°C (XLPE)
- درجة حرارة الدائرة القصيرة: up to 250°C (for a limited duration)
- Low electrical resistance due to copper conductors
The electrical performance depends on the selected conductor cross-section, installation conditions, and ambient temperature.

Mechanical and Environmental Performance
Thanks to its reinforced construction, Câble U 1000 RGPFV-RH 0.6/1kV العروض:
- High resistance to mechanical stress
- Excellent moisture and water resistance
- Good resistance to oils, fuels, and hydrocarbons
- Reliable performance in underground installations
- عمر خدمة طويل, often exceeding 30 years when properly installed
These properties make the cable suitable for demanding industrial and infrastructure applications.
التطبيقات النموذجية
Câble U 1000 RGPFV-RH 0.6/1kV is commonly used in:
- Industrial power distribution systems
- Manufacturing plants and processing facilities
- Power supply lines for heavy equipment
- Underground and buried installations
- Energy and utility infrastructure
- Public buildings and large commercial complexes
Its robust design ensures safe and continuous operation even in harsh environments.
IEC Conductor Sizes for Câble U 1000 RGPFV-RH 0.6/1kV
The following table lists IEC conductor cross-sectional areas from 0.75 mm² up to 800 مم², commonly referenced for low-voltage power cables in accordance with اللجنة الانتخابية المستقلة 60228. Actual availability may vary depending on manufacturer and project requirements.
| حجم الموصل (مم²) | IEC Class | تطبيق نموذجي |
|---|---|---|
| 0.75 | فصل 2 | Control and signal circuits |
| 1.0 | فصل 2 | Control wiring |
| 1.5 | فصل 1 / 2 | Lighting and control |
| 2.5 | فصل 2 | Small power circuits |
| 4 | فصل 2 | Power distribution |
| 6 | فصل 2 | Medium-load circuits |
| 10 | فصل 2 | Industrial power supply |
| 16 | فصل 2 | Power feeders |
| 25 | فصل 2 | Main distribution lines |
| 35 | فصل 2 | Heavy-duty power supply |
| 50 | فصل 2 | High-load distribution |
| 70 | فصل 2 | Industrial feeders |
| 95 | فصل 2 | Large equipment supply |
| 120 | فصل 2 | High-current circuits |
| 150 | فصل 2 | Main power lines |
| 185 | فصل 2 | Industrial main feeders |
| 240 | فصل 2 | High-power applications |
| 300 | فصل 2 | Specialized installations |
| 400 | فصل 2 | Large-scale power systems |
| 500 | فصل 2 | Very high current supply |
| 630 | فصل 2 | Industrial heavy-load lines |
| 800 | فصل 2 | Special large-capacity projects |
اعتبارات التثبيت
When installing Câble U 1000 RGPFV-RH 0.6/1kV, the following factors should be considered:
- Minimum bending radius according to cable diameter
- Proper trench preparation for underground installation
- Adequate mechanical protection at entry and exit points
- Compliance with local electrical installation codes
Correct installation practices are essential to fully benefit from the cable’s mechanical and electrical performance.

Advantages of Câble U 1000 RGPFV-RH 0.6/1kV
Key advantages include:
- High mechanical strength due to steel tape armour
- Excellent moisture and chemical resistance from lead sheath
- Reliable electrical performance with XLPE insulation
- Wide range of IEC conductor sizes available
- Long service life and low maintenance requirements
These advantages make the cable a preferred solution for critical low-voltage installations.
Câble U 1000 RGPFV-RH 0.6/1kV
Câble U 1000 RGPFV-RH 0.6/1kV is a robust and versatile low-voltage power cable designed for demanding fixed installations. Its combination of copper conductors, العزل XLPE, غمد الرصاص, steel tape armour, and PVC outer sheath ensures excellent electrical reliability, الحماية الميكانيكية, والمقاومة البيئية.
With IEC conductor sizes ranging from 0.75 ملم² إلى 800 مم², this cable type can be adapted to a wide variety of power and control applications. For industrial plants, مشاريع البنية التحتية, and underground power distribution systems, Câble U 1000 RGPFV-RH 0.6/1kV remains a dependable and proven solution.