1. একটি 220kV কেবল GIS টার্মিনেশন কি??
একটি 220kV তারের GIS টার্মিনেশন একটি উচ্চ-ভোল্টেজ আন্ডারগ্রাউন্ড ক্যাবলকে গ্যাস ইনসুলেটেড সুইচগিয়ারের সাথে সংযুক্ত করে (জিআইএস). It provides a safe and reliable link between the XLPE power cable and the GIS equipment.
আজ, many power utilities use GIS substations because they need less space than traditional air-insulated substations. উপরন্তু, GIS equipment offers reliable operation and requires less outdoor installation space.
তবে, connecting a 220kV XLPE cable to GIS equipment requires a special cable termination. This accessory must control the electric field, provide strong insulation, and maintain a reliable connection during long-term operation.
A 220kV Cable GIS Termination normally works with 127/220kV or other project-specific cable systems. Engineers must check the rated voltage and insulation level before selecting the product.
Unlike an outdoor cable termination, a GIS termination connects directly to a GIS bushing inside a sealed switchgear compartment. অতএব, its design must match the GIS interface and the cable structure.

2. Main Components of a 220kV GIS Cable Termination
A typical 220kV GIS cable termination contains several important parts. Each part has a clear function in the electrical and mechanical system.
2.1 অন্তরক শরীর
The insulating body provides electrical insulation between the high-voltage conductor and the grounded GIS enclosure.
Manufacturers commonly use silicone rubber or epoxy-based materials for this component. These materials offer good insulation strength and stable performance.
উপরন্তু, the insulating body must withstand normal operating voltage, lightning impulses, and switching impulses. Its design also needs to meet the requirements of the complete cable system.
2.2 Stress Control Cone
The stress control cone plays a key role in every high-voltage cable termination.
At the end of the cable insulation screen, the electric field can become very strong. If the termination does not control this stress, partial discharge may occur. সময়ের সাথে সাথে, this problem can damage the insulation.
অতএব, a 220kV Cable GIS Termination uses a stress control cone or an integrated stress control structure. This design helps spread the electric field more evenly and improves insulation reliability.
2.3 কন্ডাক্টর সংযোগকারী
The conductor connector links the cable conductor to the GIS contact system.
Depending on the cable design, the conductor may use copper or aluminum. The connector must provide good electrical contact and enough mechanical strength.
উপরন্তু, engineers must select the correct connector size according to the conductor cross-section and diameter.
2.4 GIS Plug-in Interface
The GIS plug-in interface connects the cable termination to the GIS bushing.
This component requires accurate dimensions and a suitable contact design. Even a small difference in the interface dimensions may cause installation problems.
এই কারণে, customers should provide the GIS manufacturer’s drawings and interface details before ordering a 220kV GIS cable termination.
2.5 Sealing and Grounding Parts
The sealing system protects the insulation area from moisture and external contamination. It also helps maintain the required sealing performance at the GIS connection.
এদিকে, the grounding parts connect the cable metallic screen or sheath to the substation grounding system.
The grounding arrangement depends on the cable bonding design. অতএব, engineers should confirm it during the project design stage.

3. Key Features of a 220kV Cable GIS Termination
A reliable 220kV Cable GIS Termination must offer stable electrical performance and strong mechanical design.
Its main features include:
- High insulation strength: It supports safe operation in 220kV power systems.
- Good electric field control: The stress control structure reduces local electrical stress.
- কমপ্যাক্ট ডিজাইন: It fits inside GIS equipment and helps save installation space.
- Reliable sealing: The sealing structure helps prevent moisture from entering the connection area.
- Low partial discharge: Good insulation design reduces the risk of internal electrical defects.
- Strong mechanical performance: The termination supports the mechanical loads that may occur during installation and operation.
- দীর্ঘ সেবা জীবন: Quality materials and proper design help ensure stable performance over many years.
উপরন্তু, manufacturers can design different termination sizes to match cable conductor areas, insulation thicknesses, and sheath structures.
4. 220kV GIS Termination for XLPE Power Cables
Most modern 220kV underground transmission projects use XLPE insulated power cables.
A typical 220kV XLPE cable includes the following layers:
- তামা বা অ্যালুমিনিয়াম পরিবাহী
- কন্ডাক্টর অর্ধপরিবাহী পর্দা
- XLPE নিরোধক
- অন্তরণ অর্ধপরিবাহী পর্দা
- ধাতব পর্দা, usually copper wires or tape
- Water-blocking layer, if required
- Aluminum or lead metallic sheath, depending on the design
- Outer protective jacket
The 220kV Cable GIS Termination must match the cable structure. যেমন, a copper conductor cable may need a different connector from an aluminum conductor cable.
একইভাবে, different metallic screen and sheath designs may require different grounding arrangements.
Before production, the customer should provide the following cable information:
- রেটেড ভোল্টেজ
- কন্ডাক্টর উপাদান
- Conductor cross-sectional area
- কন্ডাক্টর ব্যাস
- XLPE নিরোধক বেধ
- Insulation screen diameter
- Metallic screen structure
- Cable outer diameter
With these details, the manufacturer can check the cable dimensions and select a suitable termination design.

5. Installation Process of a 220kV Cable GIS Termination
Correct installation plays an important role in the performance of a 220kV GIS cable termination.
Because this product works in an extra-high-voltage system, qualified technicians should follow the manufacturer’s installation manual and approved project procedures.
The general installation process includes the following steps.
ধাপ 1: Prepare the Cable
প্রথম, technicians should check the cable length and installation position. They must also fix the cable securely before starting the work.
পরবর্তী, they remove the outer jacket, metallic sheath, and other cable layers according to the installation dimensions.
During this process, technicians must protect the XLPE insulation from scratches and other damage.
ধাপ 2: Prepare the Insulation Surface
After removing the required cable layers, technicians prepare the XLPE insulation surface.
The surface must remain clean, smooth, and free from dust or contamination. Any deep scratch or uneven area may affect the electric field distribution.
অতএব, technicians should use the correct tools and follow the manufacturer’s surface preparation instructions.
ধাপ 3: Install the Stress Control Component
পরবর্তী, technicians install the stress cone or integrated stress control unit.
They must place this component in the correct position because it controls the electric field around the insulation screen.
Incorrect positioning may increase electrical stress and reduce the service life of the termination.
ধাপ 4: Connect the Conductor
After preparing the cable conductor, technicians connect it to the GIS contact connector.
They must clean the contact surfaces and follow the specified tightening torque or crimping procedure.
A good conductor connection reduces contact resistance and helps prevent overheating during operation.
ধাপ 5: Connect the GIS Interface
তারপর, technicians connect the termination to the GIS bushing.
They should carefully check the alignment, insertion depth, contact position, and sealing components.
উপরন্তু, the installation team must follow the GIS manufacturer’s requirements for the plug-in connection.
ধাপ 6: Complete the Final Inspection
অবশেষে, the installation team checks the complete assembly.
They should inspect the mechanical connection, গ্রাউন্ডিং সিস্টেম, sealing parts, and cable support structure.
Depending on the project requirements, the team may also carry out electrical tests before energizing the system.

6. IEC Standards for 220kV Cable GIS Terminations
International standards help manufacturers and power utilities maintain product quality and electrical safety.
Several IEC standards are relevant to 220kV cable systems.
আইইসি 62067
আইইসি 62067 covers power cables with extruded insulation and their accessories for rated voltages above 150kV up to 500kV. অতএব, it is particularly important for 220kV XLPE cable systems.
আইইসি 62271-203
This standard covers gas-insulated metal-enclosed switchgear for rated voltages above 52kV. It provides important requirements for GIS equipment.
আইইসি 60270
আইইসি 60270 describes high-voltage test methods for partial discharge measurement. This test helps identify possible insulation defects.
আইইসি 60840
আইইসি 60840 covers extruded insulation power cables and their accessories for rated voltages above 30kV up to 150kV. Although it does not cover 220kV systems, it is relevant to lower-voltage cable projects.
For a 220kV Cable GIS Termination, engineers should pay special attention to IEC 62067 and the relevant GIS equipment requirements.
The project specification should also define the required type tests, routine tests, and acceptance tests.

7. Electrical Tests for 220kV GIS Cable Terminations
Electrical tests help confirm the insulation quality and operating performance of a 220kV cable termination.
The main tests may include the following:
Partial Discharge Test
Partial discharge testing helps detect small electrical discharges inside the insulation system.
A low partial discharge level indicates good insulation quality. অতএব, this test plays an important role in high-voltage cable accessory qualification.
Power Frequency Voltage Test
This test checks whether the insulation system can withstand the required AC test voltage for a specified period.
It helps confirm the dielectric strength of the termination.
Lightning Impulse Test
Lightning impulse testing checks the ability of the insulation system to withstand short-duration high-voltage surges.
This test is important because lightning can create high transient voltages in power transmission networks.
Switching Impulse Test
For extra-high-voltage systems, switching impulse performance also plays an important role in insulation coordination.
The test checks the termination’s ability to withstand switching overvoltages under the specified test conditions.
Thermal Cycling Test
Thermal cycling tests help evaluate the performance of cable accessories under repeated heating and cooling.
During normal operation, the conductor temperature changes with the electrical load. অতএব, the termination must maintain stable electrical and mechanical performance during these temperature changes.
The exact test sequence and acceptance limits depend on the applicable IEC standard and project requirements.

8. Applications of 220kV Cable GIS Terminations
220kV GIS cable terminations support many types of high-voltage power projects.
220kV GIS Substations
Power utilities use GIS terminations to connect underground cables to GIS switchgear in high-voltage substations.
Urban Underground Transmission
Large cities often use underground power cables to reduce the need for overhead transmission lines. GIS substations also help save valuable land.
Power Plants
Power plants use 220kV cable systems to connect transformers, সুইচগিয়ার, and transmission networks.
শিল্প সুবিধা
Large industrial plants need a stable electricity supply. A 220kV cable GIS termination helps connect their high-voltage cable circuits to GIS equipment.
নবায়নযোগ্য শক্তি প্রকল্প
Wind farms and large solar power plants may use high-voltage underground cables to connect their substations to the main power grid.
In all these applications, the correct termination design helps maintain safe and reliable power transmission.
9. How to Choose a 220kV Cable GIS Termination
Selecting the correct 220kV Cable GIS Termination requires attention to both cable and GIS equipment specifications.
Before placing an order, customers should confirm the following information:
| প্যারামিটার | Required Information |
|---|---|
| রেটেড ভোল্টেজ | 127/220kV or project-specific rating |
| কন্ডাক্টর উপাদান | তামা বা অ্যালুমিনিয়াম |
| কন্ডাক্টরের আকার | Cross-sectional area in mm² |
| Cable insulation | এক্সএলপিই |
| নিরোধক বেধ | According to cable design |
| ধাতব পর্দা | Copper wires, tape, or other structure |
| Cable outer diameter | Actual cable dimensions |
| GIS manufacturer | Brand and equipment model |
| জিআইএস ইন্টারফেস | Interface type and drawing |
| Installation position | Indoor GIS installation |
| Applicable standard | আইইসি 62067 and project specifications |
Among these parameters, GIS interface compatibility is especially important.
Different GIS manufacturers may use different bushing designs and connection dimensions. অতএব, customers should provide the GIS interface drawings before ordering.
উপরন্তু, the cable manufacturer and termination supplier should check all cable dimensions together. This step helps prevent installation problems and reduces project risks.

10. 220kV Cable GIS Termination Manufacturer – DOS Group
DOS Group is a professional manufacturer and supplier of high-voltage cable accessories and power transmission products in China.
We provide cable termination and jointing solutions for high-voltage and extra-high-voltage power systems. Our product range covers 66kV, 110কেভি, 132কেভি, 145কেভি, 220কেভি, 245কেভি, and other project-specific voltage levels.
Our main products include:
- 220kV Cable GIS Terminations
- 220kV Outdoor Cable Terminations
- High Voltage XLPE Cable Joints
- GIS Plug-in Cable Terminations
- Dry-Type Cable Terminations
- Underground Power Cable Accessories
DOS Group can develop suitable solutions according to cable specifications, GIS interface drawings, এবং প্রকল্পের প্রয়োজনীয়তা.
We work with power utilities, ইপিসি ঠিকাদার, electrical engineering companies, and international project suppliers.
If you are looking for a reliable 220kV Cable GIS Termination manufacturer or supplier, contact DOS Group. Our team can provide technical specifications, product drawings, installation manuals, and competitive quotations for your project.