2000kVA-Transformator : Vollständiger Leitfaden, Preis, Spezifikation

A 2000kVA-Transformator is one of the most widely used power transformers in medium to large-scale power distribution systems. Es liefert zuverlässige Leistung, hohe effizienz, und Flexibilität für die Industrie, kommerziell, und Infrastrukturprojekte.

If you are looking for a durable and cost-effective solution, this guide will help you understand everything about the 2000kVA-Transformator, including specifications, working principles, Anwendungen, and how DOS Group can support your project with professional manufacturing and global supply.

Transformator

What Is a 2000kVA Transformer?

A 2000kVA-Transformator is an electrical device designed to transfer electrical energy between circuits with a rated capacity of 2000 Kilovoltampere (KVA), which is equal to:

  • 2000kVA = 2MVA

It is commonly used to step down medium voltage (MV) to low voltage (LV) for end users or step up voltage in power systems.

Key Features:

  • High load capacity
  • Stable voltage regulation
  • Lange Lebensdauer
  • Suitable for continuous operation

How Does a 2000kVA Transformer Work?

The operation of a transformer is based on elektromagnetische Induktion.

Simple Working Process:

  1. Alternating current flows into the primary winding
  2. A magnetic field is created in the core
  3. This magnetic field induces voltage in the secondary winding
  4. Voltage changes according to the turns ratio

Basic Formula:

  • Spannungsverhältnis = Windungsverhältnis
  • Die Leistung bleibt nahezu konstant (minus losses)

This simple principle allows efficient transmission of electrical energy over long distances.

Transformator

Types of 2000kVA Transformers

Different environments require different transformer types. The most common types include:

1. Öltransformator

  • Uses insulating oil for cooling
  • Excellent heat dissipation
  • Suitable for outdoor installations
  • Long lifespan

2. Trockentransformator

  • Luftgekühlt, kein Öl
  • Safer for indoor use
  • Low fire risk

3. Transformator aus Gießharz

  • Encapsulated windings
  • High resistance to moisture and dust
  • Ideal for harsh environments

Technical Specifications of 2000kVA Transformer

Below is a typical specification table for a standard 2000kVA-Transformator.

Transformator

Main Technical Parameters

ArtikelParameterWert
Rated CapacityPower2000KVA
FrequenzStandard50Hz / 60Hz
PhaseTypDreiphasig
Cooling MethodOptionenONAN / EIN AUS / EIN
VektorgruppeGemeinsamDyn11 / Ja0
Impedance VoltageTypisch5% – 8%
Insulation LevelStandardKlasse a / F / H
TemperaturanstiegÖl / Wicklung55°C / 65°C
EffizienzFull Load≥ 98.5%
Tippen Sie auf WechslerTypAusladen / Unter Last
Protection LevelGehäuseIP23 / IP54
GeräuschpegelTypisch≤ 65 dB

Voltage Levels and Configurations

A 2000kVA-Transformator can be customized for different voltage systems.

Gemeinsame Primärspannungen:

  • 33kV
  • 22kV
  • 11kV
  • 10kV

Gemeinsame Sekundärspannungen:

  • 415V
  • 400V
  • 380V
  • 220V

Transformator

Output Current Calculation

The output current depends on the secondary voltage.

Formula:

Aktuell (A) = Power (kVA × 1000) ÷ (√3 × Voltage)

Aktuelle Tabelle

SekundärspannungAktuell (A)
415V~2783 A
400V~2887 A
380V~3040 A
220V~5249 A

Abmessungen und Gewicht

Typical values for a 2000kVA-Transformator:

ParameterWert
Länge2000 – 2600 mm
Breite1400 – 2000 mm
Höhe1800 – 2400 mm
Gesamtgewicht3500 – 6500 kg
Ölgewicht1200 – 2000 kg

Losses and Efficiency

Transformers are designed to minimize energy losses.

Types of Losses:

  • Leerlaufverlust (core loss)
  • Lastverlust (copper loss)

Typische Verlustwerte

TypWert
Leerlaufverlust2.0 – 3.5 kW
Lastverlust15 – 25 kW

High-quality transformers from DOS Group are optimized for low losses and high efficiency.

Transformator

Applications of 2000kVA Transformer

A 2000kVA-Transformator is widely used in various industries:

Industrial Applications

  • Produktionsstätten
  • Lebensmittelverarbeitende Fabriken
  • Mining operations

Commercial Applications

  • Einkaufszentren
  • Bürogebäude
  • Hotels and resorts

Infrastructure Projects

  • Krankenhäuser
  • Flughäfen
  • Rechenzentren

Erneuerbare Energie

  • Solar farms
  • Wind power systems

Advantages of 2000kVA Transformer

High Power Capacity

Supports large-scale operations with stable output.

Energieeffizienz

Reduces energy loss and operating costs.

Zuverlässigkeit

Ensures uninterrupted power supply.

Flexible Design

Customizable voltage, cooling, and installation options.

Transformator (2)

Installationsrichtlinien

Proper installation ensures long-term performance.

Wichtige Punkte:

  • Install on a stable foundation
  • Ensure adequate ventilation
  • Maintain safety clearance
  • Proper grounding is essential
  • Vor Feuchtigkeit und Staub schützen

Wartungstipps

Regular maintenance extends service life.

Routine Maintenance:

  • Check oil level (for oil transformers)
  • Überprüfen Sie die Isolierung
  • Monitor temperature
  • Test electrical parameters

Empfohlener Zeitplan:

  • Monthly inspection
  • Annual detailed testing

Why Choose DOS Group for 2000kVA Transformer?

Bei der Auswahl von a 2000kVA-Transformator, choosing the right manufacturer is critical. DOS Group stands out as a reliable and professional partner.

1. Strong Manufacturing Capability

  • Advanced production equipment
  • Strict quality control system
  • Compliance with IEC, ANSI standards

2. Custom Design Services

  • Voltage customization
  • Special environment solutions
  • OEM and ODM support

3. Hochwertige Materialien

  • Premium silicon steel core
  • Copper or aluminum windings
  • Durable insulation system

4. Global Export Experience

  • Serving clients worldwide
  • Wettbewerbsfähige Preise
  • Fast delivery

5. One-Stop Power Solution

DOS Group provides:

  • Transformers
  • Power cables
  • Cable accessories

This integrated supply reduces project costs and improves efficiency.

Transformator

How to Select the Right 2000kVA Transformer

Schritt 1: Calculate Load

Ensure the transformer can handle peak demand.

Schritt 2: Choose Voltage Level

Match your grid and equipment requirements.

Schritt 3: Select Type

  • Indoor → Dry-type
  • Outdoor → Oil-immersed

Schritt 4: Consider Environment

Dust, Luftfeuchtigkeit, and temperature affect selection.

Schritt 5: Choose a Trusted Supplier

A reliable manufacturer like DOS Group ensures quality and support.

Cost of 2000kVA Transformer

The price varies depending on:

  • Material (copper vs aluminum)
  • Cooling type
  • Technical specifications
  • Accessories and protection systems

Typical Price Range:

  • $15,000 – $60,000

For accurate pricing, it is best to contact DOS Group with your requirements.

Frequently Asked Questions

1. What is the lifespan of a 2000kVA transformer?

Typischerweise 20–30 years with proper maintenance.

2. Can it be used outdoors?

Yes, oil-immersed transformers are ideal for outdoor use.

3. What standards apply?

  • IEC 60076
  • ANSI C57
  • GB/T 1094

4. Is customization available?

Yes, DOS Group offers full customization services.

2000kVA-Transformator Hersteller

A 2000kVA-Transformator is a powerful and reliable solution for medium to large-scale power distribution. With proper selection, Installation, and maintenance, it can provide stable performance for decades.

Choosing a trusted manufacturer like DOS Group ensures you receive high-quality products, competitive pricing, and professional support. Whether your project is industrial, kommerziell, or renewable energy-based, a well-designed 2000kVA-Transformator is a smart investment.