Warum ist ACSR 2/0 Wachteln sind in der Energiebranche so beliebt?
Die Nachfrage nach zuverlässigen Freileitungen steigt weiter, da Länder ihre Stromübertragungssysteme ausbauen, Projekte für erneuerbare Energien, und industrielle Energieinfrastruktur. Among the most commonly used conductors in overhead distribution networks is the ACSR 2/0 Wachteldirigent.
Heute, Stromversorgungsunternehmen, EPC-Auftragnehmer, Großhändler, and industrial buyers frequently search for:
- ACSR 2/0 Wachtel
- 2/0 ACSR-Leiter
- ACSR Quail cable
- ACSR conductor supplier
- ACSR 2/0 price
- ASTM B232 ACSR
- overhead line conductor
- transmission line conductor
- aluminum conductor steel reinforced
The reason for this popularity is simple. Der ACSR Quail conductor offers excellent electrical performance, strong mechanical strength, lange lebensdauer, and competitive factory pricing.

Quick Overview of ACSR 2/0 Wachtel
| Artikel | Beschreibung |
|---|---|
| Product Name | ACSR 2/0 Wachtel |
| Full Name | Aluminiumleiter stahlverstärkt |
| Leitertyp | Overhead Transmission Conductor |
| Main Material | Aluminium + Verzinkter Stahl |
| Standard | ASTM B232 |
| Common Application | Oberleitungskraftübertragung |
| Typische Strombelastbarkeit | Ca.. 276 A |
| Main Market | Utility & Industrial Projects |
What Does ACSR Mean?
ACSR stands for:
Aluminiumleiter stahlverstärkt
This conductor combines:
- Aluminum strands for electrical conductivity
- A steel core for mechanical strength
The aluminum layer carries current efficiently, while the steel core improves tensile strength and reduces sag during long-distance installation.
Because of this design, ACSR-Leiter are widely used in overhead transmission systems worldwide.

What Does “Quail” Mean in ACSR Conductors?
The term “Quail” is part of the North American bird naming system used for ACSR conductor sizes.
Common Bird Names for ACSR Conductors
| AWG-Größe | Bird Name |
|---|---|
| 1/0 | Rabe |
| 2/0 | Wachtel |
| 3/0 | Taube |
| 4/0 | Pinguin |
daher, buyers may use different search terms such as:
- Wachteldirigent
- 2/0 Wachteldirigent
- ACSR Quail overhead cable
- Quail ACSR conductor
All of these refer to the same conductor category.
Technische Spezifikationen von ACSR 2/0 Wachtel
The following table shows the standard technical parameters of the 2/0 ACSR-Leiter.
| Technical Parameter | Typischer Wert |
|---|---|
| Leitertyp | ACSR |
| Code Name | Wachtel |
| AWG-Größe | 2/0 |
| Strand Construction | 6/1 |
| Aluminiumstränge | 6 |
| Stahlstränge | 1 |
| Durchmesser | Ca.. 11.3 mm |
| Gewicht | Ca.. 272 kg/km |
| Gleichstromwiderstand | Ca.. 0.425 Ω/km |
| Strombelastbarkeit | Ca.. 276 A |
| Standard | ASTM B232 |
Different manufacturers may provide slightly different values depending on customer specifications.

Main Applications of ACSR 2/0 Wachtel
Freileitungen
Der ACSR 2/0 Wachteldirigent is mainly used in:
- Medium-voltage transmission systems
- Utility distribution lines
- Electrical substations
- Netzausbauprojekte
Ländliche Elektrifizierungsprojekte
Governments and contractors often choose:
- overhead line conductor
- transmission line conductor
- ACSR overhead cable
because of their cost-effectiveness and durability.
Renewable Energy Infrastructure
Solar farms and wind power plants require reliable overhead conductors for grid connection systems.
Industrial Power Systems
Industrial facilities use ACSR conductors for stable outdoor electrical transmission.
Key Advantages of ACSR 2/0 Wachtel
Hohe Zugfestigkeit
The galvanized steel core improves:
- Mechanical performance
- Weitspannfähigkeit
- Resistance to wind and ice loads
Good Electrical Conductivity
Aluminum strands provide efficient current transmission.
Competitive Factory Price
Der ACSR 2/0 price is lower than equivalent copper conductor solutions.
Lange Lebensdauer
ACSR conductors are designed for long-term outdoor operation under harsh environmental conditions.

Leichtes Design
The lightweight structure helps reduce:
- Transportkosten
- Schwierigkeiten bei der Installation
- Tower loading
Ampacity of ACSR 2/0 Wachtel
Many buyers search online for:
- 2/0 ACSR ampacity
- Quail conductor current rating
- ACSR conductor ampacity chart
The typical ampacity is approximately:
Approximate Current Capacity
| Condition | Strombelastbarkeit |
|---|---|
| Standard Installation | Ca.. 276 A |
Actual ampacity depends on:
- Umgebungstemperatur
- Windgeschwindigkeit
- Installationsmethode
- Conductor spacing
- Altitude
ASTM B232 Standard Explained
Most utility projects require compliance with:
- ASTM B232 ACSR
- ASTM standard conductor
- ASTM transmission conductor
ASTM B232 Covers
- Material quality
- Strand dimensions
- Mechanische Festigkeit
- Elektrischer Widerstand
- Testverfahren
Using ASTM-compliant products helps ensure:
- Stable performance
- Long-term reliability
- International compatibility
ACSR vs AAC Conductors
Many engineers compare ACSR and AAC conductors before purchasing.
| Besonderheit | ACSR | AAC |
|---|---|---|
| Stahlkern | Ja | NEIN |
| Mechanische Festigkeit | Hoch | Medium |
| Leitfähigkeit | Very Good | Exzellent |
| Long Span Performance | Exzellent | Beschränkt |
| Hauptverwendung | Übertragung | Verteilung |
Der ACSR Quail conductor is better suited for projects requiring stronger mechanical performance.

Factors That Affect ACSR 2/0 Preis
The keyword ACSR 2/0 price is highly searched because conductor prices change regularly.
Main Pricing Factors
| Factor | Impact on Price |
|---|---|
| Aluminum Cost | Hoch |
| Steel Price | Medium |
| Bestellmenge | Hoch |
| Certification Requirements | Medium |
| Export Packaging | Medium |
| Versandkosten | Hoch |
Large-volume utility projects usually receive better factory pricing.
How to Select a Reliable ACSR Conductor Supplier
Das Richtige wählen ACSR conductor supplier is critical for project success.
Check Manufacturing Experience
Experienced manufacturers understand utility project requirements.
Verify Certifications
Reliable suppliers should provide:
- ISO-Zertifizierung
- ASTM compliance
- IEC standards
- SGS inspection reports
Request Technical Documents
Immer anfragen:
- Datasheets
- Typprüfberichte
- Factory inspection reports
Why Global Buyers Choose Chinese ACSR Manufacturers
China has become one of the largest manufacturing centers for:
- ACSR-Leiter
- AAC-Leiter
- AAAC-Leiter
- OPGW-Kabel
- overhead transmission conductors
Main Advantages of Chinese Manufacturers
| Advantage | Beschreibung |
|---|---|
| Wettbewerbsfähige Preise | Lower production costs |
| Large Production Capacity | Suitable for utility projects |
| Fast Delivery | Strong export logistics |
| OEM Support | Customized production available |
| Technische Unterstützung | International project experience |
Chinese manufacturers export extensively to:
- Latin America
- Afrika
- Südostasien
- Middle East markets
Häufig gestellte Fragen zu ACSR 2/0 Wachtel
What is the main use of ACSR 2/0 Wachtel?
It is mainly used in overhead power transmission and distribution systems.
What standard does ACSR Quail follow?
Most products comply with ASTM B232 standards.
What is the ampacity of ACSR 2/0 Wachtel?
The typical ampacity is approximately 276 A.
Is ACSR better than AAC?
For long spans and higher mechanical strength, ACSR is usually the better option.
Why is the conductor called “Quail”?
“Quail” is the bird code name assigned to the 2/0 ACSR conductor size.

ACSR 2/0 Wachteldirigent
Der ACSR 2/0 Wachteldirigent remains one of the most reliable and widely used overhead conductors in modern electrical transmission systems.
Its aluminum-steel reinforced structure provides:
- Hervorragende Leitfähigkeit
- Hohe Zugfestigkeit
- Lange Lebensdauer
- Stable outdoor performance
- Cost-effective pricing
The conductor is widely used in:
- Utility transmission networks
- Ländliche Elektrifizierungsprojekte
- Renewable energy infrastructure
- Industrielle elektrische Systeme
As a professional overhead conductor manufacturer in China, we provide:
- ACSR-Leiter
- AAC-Leiter
- AAAC-Leiter
- OPGW-Kabel
- Overhead transmission line conductors
with competitive factory prices, stable quality, schnelle Lieferung, and global export support.