YJV Cable: 0.6/1kV, Preis, Spezifikation

Low-voltage power distribution relies on reliable insulated cables. Among the many options available in the market, YJV cable is one of the most widely used types in industrial, kommerziell, und Infrastrukturprojekte. Engineers prefer it because it combines Kupferleiter, XLPE-Isolierung, and PVC outer sheath, which together provide excellent electrical performance, Haltbarkeit, and thermal resistance.

In modern electrical systems, cable selection directly affects safety, efficiency, and long-term maintenance costs. daher, understanding the Spezifikationen, current capacity, Struktur, and price factors of YJV cables helps engineers and buyers choose the right cable for their projects.

We explains the complete specification of YJV 0.6/1kV cables, including structure, Anwendungen, pricing factors, and detailed tables covering all conductor cross-sections from 0.5 mm² bis 800 mm².

YJV Cable

What is YJV Cable?

YJV is a standard Chinese cable model widely used for low-voltage power transmission and distribution.

The abbreviation means:

SymbolMeaning
YXLPE-Isolierung
JKupferleiter
VPVC sheath

daher, A YJV cable typically contains:

  • Kupferleiter
  • Vernetztes Polyethylen (XLPE) Isolierung
  • PVC-Außenmantel

Unlike PVC insulated cables, XLPE insulation withstands higher temperatures and carries higher current loads. Folglich, engineers often select YJV cables for demanding environments such as power plants, Industrieanlagen, and commercial buildings.

ZA-YJV Cable

Structure of YJV 0.6/1kV Cable

A standard YJV cable contains several functional layers.

LayerMaterialFunction
DirigentKupfer (Klasse 1 or Class 2)Conducts electrical current
IsolierungXLPEProvides electrical insulation
FillerPVC / PPMaintains cable shape
Inner sheathPVCMechanical protection
Outer sheathPVCEnvironmental protection

Because of this layered design, the cable performs well in both indoor installations and outdoor environments.

Key Advantages of YJV Cable

Many utilities and contractors choose YJV cables for several reasons.

1. Higher Temperature Rating

Erste, XLPE insulation allows continuous operation at 90°C, which is much higher than traditional PVC insulated cables.

2. Higher Current Capacity

As a result of better thermal properties, YJV cables carry larger electrical loads.

3. Excellent Mechanical Strength

Zusätzlich, PVC sheaths protect the cable against moisture, abrasion, and chemicals.

4. Lange Lebensdauer

Because of stable insulation performance, YJV cables often operate mehr als 30 Jahre in normal conditions.

U-Kabel 1000 RGPFV-RH 0.6-1kV

Applications of YJV Cable

YJV 0.6/1kV cables serve a wide variety of installations. Zum Beispiel:

  • Industrielle Stromverteilung
  • Kraftwerke
  • Commercial buildings
  • Residential electrical networks
  • Underground power transmission
  • Cable trays and ducts
  • Substations

Darüber hinaus, engineers often use these cables for large current feeders because copper conductors offer low electrical resistance.

YJV Cable

1 Core YJV Cable Specification Table

KabelartDirigentXLPE-Isolierung (mm)PVC Sheath (mm)Aktuelle Kapazität (A)
1×0.5Copper Class10.71.415
1×0.75Copper Class10.71.418
1×1Copper Class10.71.420
1×1.5Copper Class20.71.424
1×2.5Copper Class20.81.432
1×4Copper Class20.81.442
1×6Copper Class20.81.454
1×10Copper Class21.01.473
1×16Copper Class21.01.598
1×25Copper Class21.21.6129
1×35Copper Class21.21.6158
1×50Copper Class21.41.8192
1×70Copper Class21.41.8245
1×95Copper Class21.62.0298
1×120Copper Class21.62.0341
1×150Copper Class21.82.2391
1×185Copper Class22.02.4448
1×240Copper Class22.22.6523
1×300Copper Class22.42.8596
1×400Copper Class22.63.0693
1×500Copper Class22.83.2784
1×630Copper Class23.03.4886
1×800Copper Class23.23.61002

2 Core YJV Cable Table (Up to 2×630)

KabelartDirigentXLPE-IsolierungPVC SheathAktuelle Kapazität
2×1.5Copper Class20.7mm1.6mm20A
2×2.5Copper Class20.8mm1.6mm27A
2×4Copper Class20.8mm1.8mm36A
2×6Copper Class20.8mm1.8mm46A
2×10Copper Class21.0mm1.8mm63A
2×16Copper Class21.0mm2.0mm85A
2×25Copper Class21.2mm2.0mm112A
2×35Copper Class21.2mm2.2mm138A
2×50Copper Class21.4mm2.2mm168A
2×70Copper Class21.4mm2.4mm213A
2×95Copper Class21.6mm2.6mm258A
2×120Copper Class21.6mm2.8mm296A
2×150Copper Class21.8mm2.8mm338A
2×185Copper Class22.0mm3.0mm387A
2×240Copper Class22.2mm3.2mm452A
2×300Copper Class22.4mm3.2mm515A
2×400Copper Class22.6mm3.4mm600A
2×500Copper Class22.8mm3.6mm680A
2×630Copper Class23.0mm3.8mm770A

3 Core YJV Cable Table

KabelartDirigentXLPE-IsolierungPVC SheathAktuelle Kapazität
3×1.5Copper Class20.7mm1.6mm18A
3×2.5Copper Class20.8mm1.6mm24A
3×4Copper Class20.8mm1.8mm32A
3×6Copper Class20.8mm1.8mm41A
3×10Copper Class21.0mm2.0mm57A
3×16Copper Class21.0mm2.2mm76A
3×25Copper Class21.2mm2.4mm101A
3×35Copper Class21.2mm2.6mm125A
3×50Copper Class21.4mm2.6mm150A
3×70Copper Class21.4mm2.8mm192A
3×95Copper Class21.6mm3.0mm232A
3×120Copper Class21.6mm3.2mm265A
3×150Copper Class21.8mm3.2mm302A
3×185Copper Class22.0mm3.4mm345A
3×240Copper Class22.2mm3.6mm403A
3×300Copper Class22.4mm3.8mm460A

3+1 Core YJV Cable Table

KabelartDirigentXLPE-IsolierungPVC SheathAktuelle Kapazität
3×4+1×2.5Kupfer0.8mm1.8mm32A
3×6+1×4Kupfer0.8mm1.8mm41A
3×10+1×6Kupfer1.0mm2.0mm57A
3×16+1×10Kupfer1.0mm2.2mm76A
3×25+1×16Kupfer1.2mm2.4mm101A
3×35+1×16Kupfer1.2mm2.6mm125A
3×50+1×25Kupfer1.4mm2.6mm150A
3×70+1×35Kupfer1.4mm2.8mm192A
3×95+1×50Kupfer1.6mm3.0mm232A
3×120+1×70Kupfer1.6mm3.2mm265A
3×150+1×70Kupfer1.8mm3.2mm302A
3×185+1×95Kupfer2.0mm3.4mm345A
3×240+1×120Kupfer2.2mm3.6mm403A
3×300+1×150Kupfer2.4mm3.8mm460A

3+2 Core YJV Cable Table

KabelartDirigentXLPE-IsolierungPVC SheathAktuelle Kapazität
3×10+2×6Kupfer1.0mm2.0mm57A
3×16+2×10Kupfer1.0mm2.2mm76A
3×25+2×16Kupfer1.2mm2.4mm101A
3×35+2×16Kupfer1.2mm2.6mm125A
3×50+2×25Kupfer1.4mm2.6mm150A
3×70+2×35Kupfer1.4mm2.8mm192A
3×95+2×50Kupfer1.6mm3.0mm232A
3×120+2×70Kupfer1.6mm3.2mm265A
3×150+2×70Kupfer1.8mm3.2mm302A
3×185+2×95Kupfer2.0mm3.4mm345A
3×240+2×120Kupfer2.2mm3.6mm403A
3×300+2×150Kupfer2.4mm3.8mm460A

4+1 Core YJV Cable Table

KabelartDirigentXLPE-IsolierungPVC SheathAktuelle Kapazität
4×10+1×6Kupfer1.0mm2.0mm57A
4×16+1×10Kupfer1.0mm2.2mm76A
4×25+1×16Kupfer1.2mm2.4mm101A
4×35+1×16Kupfer1.2mm2.6mm125A
4×50+1×25Kupfer1.4mm2.6mm150A
4×70+1×35Kupfer1.4mm2.8mm192A
4×95+1×50Kupfer1.6mm3.0mm232A
4×120+1×70Kupfer1.6mm3.2mm265A
4×150+1×70Kupfer1.8mm3.2mm302A
4×185+1×95Kupfer2.0mm3.4mm345A
4×240+1×120Kupfer2.2mm3.6mm403A
4×300+1×150Kupfer2.4mm3.8mm460A

5 Core YJV Cable Table

KabelartDirigentXLPE-IsolierungPVC SheathAktuelle Kapazität
5×10Kupfer1.0mm2.0mm50A
5×16Kupfer1.0mm2.2mm68A
5×25Kupfer1.2mm2.4mm90A
5×35Kupfer1.2mm2.6mm110A
5×50Kupfer1.4mm2.6mm135A
5×70Kupfer1.4mm2.8mm173A
5×95Kupfer1.6mm3.0mm210A
5×120Kupfer1.6mm3.2mm240A
5×150Kupfer1.8mm3.2mm273A
5×185Kupfer2.0mm3.4mm312A
5×240Kupfer2.2mm3.6mm365A
5×300Kupfer2.4mm3.8mm420A

NH-YJV Cable

YJV Cable Price

The price of YJV cable varies depending on several factors.

Copper Price

Erstens, copper accounts for 70–85% of cable cost, so market fluctuations strongly affect pricing.

Leitergröße

Larger cross-sections obviously require more copper, which increases the price significantly.

Cable Structure

Multi-core cables require fillers and additional sheathing, so they cost more than single-core cables.

Order Quantity

Large project orders usually receive lower factory prices.

Typical reference price range:

KabelartPrice Range
Small LV cable$0.5 $2 / meter
Medium size$3 $20 / meter
Large power cable$20 $120 / meter

YJV – Kupferleiter, XLPE-Isolierung, and PVC sheaths

YJV 0.6/1kV cables play a crucial role in modern electrical systems. Because they combine Kupferleiter, XLPE-Isolierung, and PVC sheaths, they provide excellent electrical performance, mechanischer Schutz, und lange Lebensdauer.

Außerdem, engineers can select from many core configurations, einschließlich 1 Kern, 2 Kern, 3 Kern, 3+1 Kern, 3+2 Kern, 4+1 Kern, Und 5 core cables. This flexibility allows YJV cables to meet the needs of industrial plants, buildings, and power distribution networks.

Endlich, when selecting a cable, engineers should carefully evaluate Leitergröße, installation environment, and required current capacity. By doing so, they ensure both electrical safety and long-term reliability.