1. What Is a 220kV Cable GIS Termination?
A 220kV Cable GIS Termination connects a high-voltage underground cable to Gas Insulated Switchgear (ГИС). It provides a safe and reliable link between the XLPE power cable and the GIS equipment.
Сегодня, many power utilities use GIS substations because they need less space than traditional air-insulated substations. Кроме того, GIS equipment offers reliable operation and requires less outdoor installation space.
Однако, connecting a 220kV XLPE cable to GIS equipment requires a special cable termination. This accessory must control the electric field, provide strong insulation, and maintain a reliable connection during long-term operation.
A 220kV Cable GIS Termination normally works with 127/220kV or other project-specific cable systems. Engineers must check the rated voltage and insulation level before selecting the product.
В отличие от наружной заделки кабеля, a GIS termination connects directly to a GIS bushing inside a sealed switchgear compartment. Поэтому, its design must match the GIS interface and the cable structure.

2. Main Components of a 220kV GIS Cable Termination
A typical 220kV GIS cable termination contains several important parts. Each part has a clear function in the electrical and mechanical system.
2.1 Изоляционный корпус
The insulating body provides electrical insulation between the high-voltage conductor and the grounded GIS enclosure.
Manufacturers commonly use silicone rubber or epoxy-based materials for this component. These materials offer good insulation strength and stable performance.
Кроме того, the insulating body must withstand normal operating voltage, lightning impulses, and switching impulses. Its design also needs to meet the requirements of the complete cable system.
2.2 Stress Control Cone
The stress control cone plays a key role in every high-voltage cable termination.
At the end of the cable insulation screen, the electric field can become very strong. If the termination does not control this stress, partial discharge may occur. Через некоторое время, this problem can damage the insulation.
Поэтому, a 220kV Cable GIS Termination uses a stress control cone or an integrated stress control structure. This design helps spread the electric field more evenly and improves insulation reliability.
2.3 Разъем проводника
The conductor connector links the cable conductor to the GIS contact system.
В зависимости от конструкции кабеля, the conductor may use copper or aluminum. The connector must provide good electrical contact and enough mechanical strength.
Более того, engineers must select the correct connector size according to the conductor cross-section and diameter.
2.4 GIS Plug-in Interface
The GIS plug-in interface connects the cable termination to the GIS bushing.
This component requires accurate dimensions and a suitable contact design. Even a small difference in the interface dimensions may cause installation problems.
По этой причине, customers should provide the GIS manufacturer’s drawings and interface details before ordering a 220kV GIS cable termination.
2.5 Sealing and Grounding Parts
The sealing system protects the insulation area from moisture and external contamination. It also helps maintain the required sealing performance at the GIS connection.
Тем временем, the grounding parts connect the cable metallic screen or sheath to the substation grounding system.
The grounding arrangement depends on the cable bonding design. Поэтому, engineers should confirm it during the project design stage.

3. Key Features of a 220kV Cable GIS Termination
A reliable 220kV Cable GIS Termination must offer stable electrical performance and strong mechanical design.
Its main features include:
- High insulation strength: It supports safe operation in 220kV power systems.
- Good electric field control: The stress control structure reduces local electrical stress.
- Компактный дизайн: It fits inside GIS equipment and helps save installation space.
- Reliable sealing: The sealing structure helps prevent moisture from entering the connection area.
- Low partial discharge: Good insulation design reduces the risk of internal electrical defects.
- Strong mechanical performance: The termination supports the mechanical loads that may occur during installation and operation.
- Длительный срок службы: Quality materials and proper design help ensure stable performance over many years.
Кроме того, manufacturers can design different termination sizes to match cable conductor areas, insulation thicknesses, and sheath structures.
4. 220kV GIS Termination for XLPE Power Cables
Most modern 220kV underground transmission projects use XLPE insulated power cables.
A typical 220kV XLPE cable includes the following layers:
- Медный или алюминиевый проводник
- Проводниковый полупроводниковый экран
- Изоляция из сшитого полиэтилена
- Изоляционный полупроводниковый экран
- Металлический экран, usually copper wires or tape
- Water-blocking layer, if required
- Aluminum or lead metallic sheath, в зависимости от дизайна
- Outer protective jacket
The 220kV Cable GIS Termination must match the cable structure. Например, a copper conductor cable may need a different connector from an aluminum conductor cable.
Сходным образом, different metallic screen and sheath designs may require different grounding arrangements.
Before production, the customer should provide the following cable information:
- Номинальное напряжение
- Материал проводника
- Площадь поперечного сечения проводника
- Диаметр проводника
- Толщина изоляции из сшитого полиэтилена
- Insulation screen diameter
- Металлическая конструкция экрана
- Внешний диаметр кабеля
With these details, the manufacturer can check the cable dimensions and select a suitable termination design.

5. Installation Process of a 220kV Cable GIS Termination
Correct installation plays an important role in the performance of a 220kV GIS cable termination.
Because this product works in an extra-high-voltage system, qualified technicians should follow the manufacturer’s installation manual and approved project procedures.
The general installation process includes the following steps.
Шаг 1: Подготовьте кабель
Первый, technicians should check the cable length and installation position. They must also fix the cable securely before starting the work.
Следующий, they remove the outer jacket, металлическая оболочка, and other cable layers according to the installation dimensions.
Во время этого процесса, technicians must protect the XLPE insulation from scratches and other damage.
Шаг 2: Prepare the Insulation Surface
After removing the required cable layers, technicians prepare the XLPE insulation surface.
The surface must remain clean, smooth, and free from dust or contamination. Any deep scratch or uneven area may affect the electric field distribution.
Поэтому, technicians should use the correct tools and follow the manufacturer’s surface preparation instructions.
Шаг 3: Install the Stress Control Component
Следующий, technicians install the stress cone or integrated stress control unit.
They must place this component in the correct position because it controls the electric field around the insulation screen.
Incorrect positioning may increase electrical stress and reduce the service life of the termination.
Шаг 4: Подключите проводник
After preparing the cable conductor, technicians connect it to the GIS contact connector.
They must clean the contact surfaces and follow the specified tightening torque or crimping procedure.
A good conductor connection reduces contact resistance and helps prevent overheating during operation.
Шаг 5: Подключите ГИС-интерфейс
Затем, technicians connect the termination to the GIS bushing.
They should carefully check the alignment, глубина вставки, contact position, and sealing components.
Кроме того, the installation team must follow the GIS manufacturer’s requirements for the plug-in connection.
Шаг 6: Complete the Final Inspection
Окончательно, the installation team checks the complete assembly.
They should inspect the mechanical connection, система заземления, уплотнительные детали, and cable support structure.
В зависимости от требований проекта, the team may also carry out electrical tests before energizing the system.

6. IEC Standards for 220kV Cable GIS Terminations
International standards help manufacturers and power utilities maintain product quality and electrical safety.
Several IEC standards are relevant to 220kV cable systems.
МЭК 62067
МЭК 62067 covers power cables with extruded insulation and their accessories for rated voltages above 150kV up to 500kV. Поэтому, it is particularly important for 220kV XLPE cable systems.
МЭК 62271-203
This standard covers gas-insulated metal-enclosed switchgear for rated voltages above 52kV. It provides important requirements for GIS equipment.
МЭК 60270
МЭК 60270 describes high-voltage test methods for partial discharge measurement. This test helps identify possible insulation defects.
МЭК 60840
МЭК 60840 covers extruded insulation power cables and their accessories for rated voltages above 30kV up to 150kV. Although it does not cover 220kV systems, it is relevant to lower-voltage cable projects.
For a 220kV Cable GIS Termination, engineers should pay special attention to IEC 62067 and the relevant GIS equipment requirements.
The project specification should also define the required type tests, routine tests, and acceptance tests.

7. Electrical Tests for 220kV GIS Cable Terminations
Electrical tests help confirm the insulation quality and operating performance of a 220kV cable termination.
The main tests may include the following:
Тест частичного разряда
Partial discharge testing helps detect small electrical discharges inside the insulation system.
A low partial discharge level indicates good insulation quality. Поэтому, this test plays an important role in high-voltage cable accessory qualification.
Power Frequency Voltage Test
This test checks whether the insulation system can withstand the required AC test voltage for a specified period.
It helps confirm the dielectric strength of the termination.
Lightning Impulse Test
Lightning impulse testing checks the ability of the insulation system to withstand short-duration high-voltage surges.
This test is important because lightning can create high transient voltages in power transmission networks.
Switching Impulse Test
For extra-high-voltage systems, switching impulse performance also plays an important role in insulation coordination.
The test checks the termination’s ability to withstand switching overvoltages under the specified test conditions.
Thermal Cycling Test
Thermal cycling tests help evaluate the performance of cable accessories under repeated heating and cooling.
During normal operation, the conductor temperature changes with the electrical load. Поэтому, the termination must maintain stable electrical and mechanical performance during these temperature changes.
The exact test sequence and acceptance limits depend on the applicable IEC standard and project requirements.

8. Applications of 220kV Cable GIS Terminations
220kV GIS cable terminations support many types of high-voltage power projects.
220kV GIS Substations
Power utilities use GIS terminations to connect underground cables to GIS switchgear in high-voltage substations.
Городская подземная передача
Large cities often use underground power cables to reduce the need for overhead transmission lines. GIS substations also help save valuable land.
Power Plants
Power plants use 220kV cable systems to connect transformers, распределительное устройство, и сети передачи.
Промышленные объекты
Large industrial plants need a stable electricity supply. A 220kV cable GIS termination helps connect their high-voltage cable circuits to GIS equipment.
Проекты возобновляемой энергетики
Wind farms and large solar power plants may use high-voltage underground cables to connect their substations to the main power grid.
In all these applications, the correct termination design helps maintain safe and reliable power transmission.
9. How to Choose a 220kV Cable GIS Termination
Selecting the correct 220kV Cable GIS Termination requires attention to both cable and GIS equipment specifications.
Before placing an order, customers should confirm the following information:
| Параметр | Required Information |
|---|---|
| Номинальное напряжение | 127/220kV or project-specific rating |
| Материал проводника | Медь или алюминий |
| Размер проводника | Cross-sectional area in mm² |
| Изоляция кабеля | СПЭ |
| Толщина изоляции | По конструкции кабеля |
| Металлический экран | Медные провода, tape, or other structure |
| Внешний диаметр кабеля | Actual cable dimensions |
| производитель ГИС | Brand and equipment model |
| ГИС-интерфейс | Interface type and drawing |
| Installation position | Indoor GIS installation |
| Применимый стандарт | МЭК 62067 и спецификации проекта |
Among these parameters, GIS interface compatibility is especially important.
Different GIS manufacturers may use different bushing designs and connection dimensions. Поэтому, customers should provide the GIS interface drawings before ordering.
Более того, the cable manufacturer and termination supplier should check all cable dimensions together. This step helps prevent installation problems and reduces project risks.

10. 220kV Cable GIS Termination Manufacturer – DOS Group
DOS Group является профессиональным производителем и поставщиком аксессуаров для высоковольтных кабелей и продукции для передачи электроэнергии в Китае..
We provide cable termination and jointing solutions for high-voltage and extra-high-voltage power systems. Our product range covers 66kV, 110кВ, 132кВ, 145кВ, 220кВ, 245кВ, and other project-specific voltage levels.
Our main products include:
- 220kV Cable GIS Terminations
- 220kV Outdoor Cable Terminations
- High Voltage XLPE Cable Joints
- GIS Plug-in Cable Terminations
- Dry-Type Cable Terminations
- Underground Power Cable Accessories
DOS Group can develop suitable solutions according to cable specifications, GIS interface drawings, и требования к проекту.
We work with power utilities, EPC-подрядчики, электротехнические компании, and international project suppliers.
If you are looking for a reliable 220kV Cable GIS Termination manufacturer or supplier, contact DOS Group. Our team can provide technical specifications, product drawings, installation manuals, and competitive quotations for your project.